TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
AIR PRESSURE TEST
(1) Open LH and RH catwalks.
(2) Disconnect air hose from output 90 degree
fitting of shuttle valve.
(3) Remove tube nipple from M1089 30K
winch pneumatic test adapter.
(4) Connect M1089 30K winch pneumatic
test adapter to output 90 degree fitting of
shuttle valve.
(5) Install STE/ICE-R 0-1000 PSI transducer on
M1089 30K winch pneumatic test adapter.
(6) Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(7) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(8) If 55-65 PSI (340-448 kPa) is not present,
go to step 3 of this fault.
(9) Shut down engine (TM 9-2320-366-10-1).
(10) Drain air tanks (TM9-2320-366-10-1).
NOTE
Air pressure trapped in wrecker air
system will be released when
disconnecting M1089 30K winch
pneumatic test adapter from output 90
degree fitting.
(11) Disconnect M1089 30K winch pneumatic
test adapter from output 90 degree
fitting of shuttle valve.
(12) Connect air hose to output 90 degree
fitting of shuttle valve.
(13) Install tube nipple on M1089 30K winch
pneumatic test adapter.
Change 1
|