TM 9-2320-366-20-3
(PLGR)
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Circuit breaker CB7 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at
REASON FOR QUESTION
terminal lug TL9?
POSSIBLE PROBLEMS
If 24 VDC is not present, go to
step 2 of this fault. If 24 VDC
Faulty circuit breaker CB7.
is present, perform Precision
Faulty digitization rack power
Lightweight Global
supply.
Positioning System Receiver
Faulty Precision Lightweight
(PLGR) troubleshooting.
Global Positioning System
Receiver (PLGR).
NO
YES
Go to step 2 of this fault.
Contact supervisor, Precision Lightweight Global
Positioning System Receiver (PLGR) troubleshooting
needs to be performed.
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |