TM 9-2320-366-20-3
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Circuit breaker CB5 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at
REASON FOR QUESTION
terminal lug TL8?
POSSIBLE PROBLEMS
If 24 VDC is not present, go to
step 2 of this fault. If 24 VDC
Faulty circuit breaker CB5.
is present, perform Enhanced
Faulty digitization rack power
Position Location Reporting
supply.
System (EPLRS)
Faulty Enhanced
troubleshooting.
Position Location Reporting
System (EPLRS).
NO
YES
Go to step 2 of this fault.
Contact supervisor, Ehanced Position
Location Reporting System (EPLRS)
troubleshooting needs to be performed.
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |