TM 9-2320-366-20-3
INITIAL SETUP
Equipment Conditions
Tools/Special Tools
Engine shut down (TM 9-2320-366-10-2)
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Personnel Required
(2)
START
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
1.
Voltage Test or
Circuit breaker CB1 is not
STE/ICE-R Test #89
tripped.
Is 24 VDC present at
REASON FOR QUESTION
terminal lug TL6?
POSSIBLE PROBLEMS
If 24 VDC is not present, go to
Faulty circuit breaker CB1.
step 2 of this fault. If 24 VDC
Faulty power cable from
is present perform Mobile
terminal lug TL15 to terminal
Tracking System (MTS) Sense
lug TL22.
troubleshooting.
Faulty Power Distribution Panel
(PD2).
NO
Faulty Mobile Tracking System
(MTS) Sense.
YES
Go to step 2 of this fault.
Contact supervisor, Mobile Tracking System
(MTS) Sense troubleshooting needs to be
performed.
Change 2
|