TM 9-2320-366-20-3
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Remove wing screw from power
distribution shelf.
(2) Loosen wing screw on electrical
distribution block cover.
(3) Remove electrical distribution block cover
from power distribution shelf.
(4) Set multimeter to volts DC.
(5) Connect positive (+) probe of multimeter to
terminal lug TL6.
(6) Connect negative (-) probe of multimeter to
known good ground.
(7) Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(8) Position master power switch to off
(TM 9-2320-366-10-1).
(9) If 24 VDC is not present, go to step 2 of
this fault.
(10) If 24 VDC is present, contact supervisor,
Mobile Tracking System (MTS) Sense
troubleshooting needs to be performed.
Change 2
2-2283
|