x1. NO POWER TO DIGITIZATION RACK (CONT)
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
4.
Voltage Test or
Circuit breaker CB11 not tripped.
STE/ICE-R Test #89
Power cable from terminal lug
Is 24 VDC present at terminal
TL24 to terminal lug TL20 OK.
REASON FOR QUESTION
lug TL23?
POSSIBLE PROBLEMS
If 24 VDC is not present, circuit
breaker CB11 is faulty. If 24
Faulty circuit breaker CB11.
VDC is present, power cable
Faulty power cable from terminal
from terminal lug TL23 to
lug TL23 to terminal lug TL16.
terminal lug TL16 is faulty.
NO
Replace circuit breaker CB11
YES
(para 20-81).
Replace power cable from terminal
TL23 to terminal TL16 (para 20-81).