TM 9-2320-366-20-3
x1. NO POWER TO DIGITIZATION RACK (CONT)
WARNING
Read WARNING
TEST OPTIONS
TEST OPTIONS
on following page.
3.
Voltage Test or
Circuit breaker CB11 not tripped.
STE/ICE-R Test #89
Is 24 VDC present at
POSSIBLE PROBLEMS
REASON FOR QUESTION
terminal lug TL24?
Faulty circuit breaker CB11.
If 24 VDC is not present,
Faulty power cable from
power cable from terminal lug
terminal lug TL24 to terminal
TL24 to terminal lug TL20 is
lug TL20.
faulty.
Faulty power cable from
terminal lug TL23 to terminal
lug TL16.
NO
Replace power cable from
YES
terminal lug TL24 to terminal
lug TL20 (para 20-81).