(1) Remove three screws and washers from
Power Distribution Panel (PDP).
(2) Remove three screws from Power Distribution
Panel (PDP).
(3) Lift Power Distribution Panel (PDP) to gain
access.
(4) Push in reset button on circuit breaker CB11
to see if it is tripped.
(5) If circuit breaker CB11 is not tripped, go to
step 3 of this fault.
(6) If circuit breaker CB11 trips agian, replace
circuit breaker CB11 (para 20-81).
NOTE
Perform steps (7) through (9) if circuit
breaker CB11 is faulty.
(7) Position electrical distribution block cover on
power distribution shelf.
(8) Tighten wing screw on electrical distribution
block cover.
(9) Install wing screw in power distribution shelf.
Change 2