x1. NO POWER TO DIGITIZATION RACK (CONT)
TEST OPTIONS
TEST OPTIONS
2.
Nothing.
Visual Inspection
Is circuit breaker CB11
POSSIBLE PROBLEMS
REASON FOR QUESTION
tripped?
Circuit breaker CB11 tripped.
If circuit breaker CB11 is
Faulty circuit breaker CB11.
tripped, digitization rack will
Faulty power cable from
not have power.
terminal
lug TL24 to terminal lug TL20.
Faulty power cable from
terminal
NO
lug TL23 to terminal lug TL16.
YES
Go to step 3 of this fault.
Reset circuit breaker CB11.
If circuit breaker CB11, trips agian
replace circuit breaker CB11
(para 20-81).