TM 9-2320-366-20-2
e148. M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE (CONT)
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
12.
Voltage Test or
Circuit breakers CB71, CB72,
STE/ICE-R Test #89
and CB74 OK.
Is 12 VDC present at
REASON FOR QUESTION
Hazard lights illuminate.
diode D2B terminal 3?
Light bulb OK.
If 12 VDC is not present, diode
Auxiliary panel cable
D2B is faulty. If 12 VDC is
assembly OK.
present, wire 1672 is faulty.
Relay K9 OK.
Worklights switch OK.
Relay K12 OK.
POSSIBLE PROBLEMS
NO
Faulty dashboard cable
assembly.
Faulty diode D2B.
Replace diode D2B
YES
(para 7-9).
Repair wire 1672 from diode D2B
terminal 3 on PDP to connector P913
socket 3 (para 2-45) or replace WTEC II
dashboard cable assembly (para 7-10)
or WTEC III dashboard cable assembly
(para 7-11).
2-1556
Change 1
|