TM 9-2320-366-20-2
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Set multimeter to volts DC.
(2) Connect positive (+) probe of multimeter
to PDP, where diode D2B terminal 3 was
removed.
(3) Connect negative (-) probe of multimeter
to ground.
(4) Position main light switch to STOP LIGHT
(TM 9-2320-366-10-1) and note reading on
(5) If 12 VDC is not present, replace diode
D2B (para 7-9).
(6) If 12 VDC is present, repair wire 1672
from diode D2B terminal 3 on PDP to
connector P913 socket 3 (para 2-45) or
replace WTEC II dashboard cable
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(7) Position main light switch to OFF
(TM 9-2320-366-10-1).
(8) Install diode D2B in PDP.
(9) Install PDP cover (para 16-2).
(10) Connect connector P905 to worklights
switch.
(11) Position auxiliary panel on auxiliary
panel housing with six screws.
(12) Tighten six screws to 24 lb-in. (3 Nm).
Change 1
2-1557
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |