TM 9-2320-366-20-2
e143. M1090/M1094 DUMP BODY DOES NOT RAISE (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
9.
Continuity Test or
Hydraulic oil level OK.
STE/ICE-R Test #91
PTO OK.
Is continuity present from
REASON FOR QUESTION
Circuit breaker CB50 OK.
connector P911 socket 3 to
connector P909 socket 5?
If continuity is not present,
POSSIBLE PROBLEMS
wire 2006 in auxiliary panel
Faulty auxiliary panel
cable assembly is faulty.
cable assembly.
Faulty dashboard cable
assembly.
NO
Repair wire 2006 from connector P911
socket 3 to connector P909 socket 5
YES
(para 2-45) or replace auxiliary panel cable
assembly (para 7-58).
2-1490.4
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |