WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuit
and cause severe burns or electrical shock.
VOLTAGE TEST
(1) Connect wrecker remote control cable to RH
remote control bulkhead connector
(TM 9-2320-366-10-1).
(2) Set multimeter to vdc.
(3) Connect positive (+) probe of multimeter to
terminal listed in Table 2-13. Actuator
(4) Connect negative (-) probe of multimeter on
ground.
(5) Position master power switch to on
(TM 9-2320-366-10-1).
(6) Position remote control box switch to position
listed in Table 2-13. Actuator Voltage Test
and note reading on multimeter.
(7) If 24 vdc is not present, go to step 3 of this
fault.
(8) Position master power switch to off
(TM 9-2320-366-10-1).
(9) Disconnect remote control cable from RH
remote control bulkhead connector
(TM 9-2320-366-10-1).
TABLE 2-13. ACTUATOR VOLTAGE TEST
Remote Control Box
TB No.
ACTUATOR NAME
Switch Position
2
Underlift fold up
UP
3
Stinger in
IN
4
Underlift up
UP
6
Main winch LH in
IN
8
Main winch RH in
IN
11
Main winch RH out
OUT
12
Main winch speed RH high
HIGH
13
Main winch LH out
OUT
14
Main winch speed LH high
HIGH
15
Underlift down
DOWN
16
Stinger out
OUT
17
Underlift fold down
DOWN