e100. START INHIBIT PUSHBUTTON DOES NOT OPERATE (CONT)
e100.
KNOWN INFO
TEST OPTIONS
4.
Engine will start after start
Continuity Test or
inhibit pushbutton switch
STE/ICE-R #91
Is continuity present
REASON FOR QUESTION
is pressed.
between relay K19
If continuity is not present,
Start inhibit pushbutton
terminal 85 and a known
wire 3016 is faulty. If
switch OK.
good ground?
continuity is present, relay
Wire 1463 OK.
K19 is faulty.
Wire 1637 OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
NO
assembly.
Repair wire 3016 (para 2-45)
Faulty relay K19.
or replace WTEC II dashboard cable
YES
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
Replace relay K19