TM 9-2320-366-20-2
TM
e97. ETHER START DOES NOT OPERATE (CONT)
e97.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
4.
Circuit breaker OK.
Voltage Test or
on following page.
Ether cylinder OK.
STE/ICE-R #89
Is 24 vdc present at
REASON FOR QUESTION
Start and charging
connector PX13-1?
If 24 vdc is not present,
cable assembly OK.
wire 1401 is faulty.
Ether valve OK.
Ether start switch OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
NO
assembly.
Repair wire 1401 (para 2-45)
Faulty engine control cable
or replace WTEC II dashboard cable
assembly.
YES
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
KNOWN INFO
TEST OPTIONS
5.
Circuit breaker OK.
Continuity Test or
Is continuity present from
Ether cylinder OK.
STE/ICE-R #91
REASON FOR QUESTION
connector J31-2 to
Start and charging cable
If continuity is not present,
connector PX13-3?
assembly OK.
wire 1402 is faulty.
Ether valve OK.
Ether start switch OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
NO
assembly.
Repair wire 1402 (para 2-45)
Faulty engine control cable
or replace WTEC II dashboard cable
assembly.
YES
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
2-1114
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |