CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J93-2.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3014
(para 2-45) or replace start and charging cable
assembly (para 7-132).
(5)
If continuity is present, replace ether valve
(para 4-15).
(6)
Raise spare tire (TM 9-2320-366-10-1).
CONTINUITY TEST
(1)
Remove instrument panel assembly for access
(para 7-15).
(2)
Disconnect connector PX13 from ether start
switch.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
ether start switch terminal 1.
(5)
Connect negative (-) probe of multimeter to
ether start switch terminal 3.
(6)
Position ether start switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(7)
If continuity is not present, replace ether
start switch (para 7-18).