TM 9-2320-366-20-1
TM
e33. FAN OFF INDICATOR DOES NOT OPERATE (CONT)
e33.
KNOWN INFO
TEST OPTIONS
3.
Other indicator lights
Continuity Test or
operate.
STE/ICE-R #91
Is continuity present
Lighted indicator
REASON FOR QUESTION
between connector PX7-26
display OK.
If continuity is not
and connector PX1-6?
POSSIBLE PROBLEMS
present, wire 1814 is
Faulty dashboard cable
faulty.
assembly.
Faulty radiator fan off
switch.
NO
Repair wire 1814 (para 2-45)
YES
or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
KNOWN INFO
TEST OPTIONS
4.
Other indicator lights
Continuity Test or
operate.
STE/ICE-R #91
Is continuity present
Fan off indicator lamps OK.
REASON FOR QUESTION
between connector PX1-2
Lighted indicator
If continuity is not present,
and a known good ground?
display OK.
wire 3023 is faulty. If
POSSIBLE PROBLEMS
continuity is present,
Faulty dashboard cable
radiator fan off switch is
assembly.
faulty.
Faulty radiator fan off
NO
switch.
Repair wire 3023 (para 2-45)
YES
or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
Replace radiator fan off
switch (para 7-18).
2-486
|