Page Title: CONTINUITY TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Remove instrument panel assembly for access
(para 7-15).
(2)
Disconnect connector PX1 from radiator fan
off switch.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
connector PX7-26.
(5)
Connect negative (-) probe of multimeter to
connector PX1-6 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 1814
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX1-2.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3023
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(5)
If continuity is present, replace radiator fan off
switch (para 7-18).
(6)
Connect connector PX1 to radiator fan off
switch.
(7)
Install instrument panel assembly (para 7-15).
(8)
Connect lighted indicator display to connector
PX7.
(9)
Position lighted indicator display in instrument
panel assembly with four screws.
(10)
Tighten four screws to 6-10 lb-in. (1 Nm).
(11)
Connect batteries (para 7-57).
2-487