TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Loosen four captive screws in lamp mounting
panel.
(2)
Remove lamp mounting panel from lighted
indicator display housing.
(3)
Remove fan off indicator lamps from printed
circuit board.
(4)
Set multimeter to ohms.
(5)
Check continuity through each fan off indicator
lamp and note reading on multimeter.
(6)
If continuity is not present, replace fan off
indicator lamps (para 7-16).
(7)
If continuity is present, replace lighted
indicator display (para 7-16).
(8)
Install fan off indicator lamps in printed
circuit board.
(9)
Install lamp mounting panel in lighted indicator
display housing.
(10)
Tighten four captive screws in lamp mounting
panel.
(11)
Connect lighted indicator display to connector
PX7.
(12)
Position lighted indicator display in instrument
panel assembly with four screws.
(13)
Tighten four screws to 6-10 lb-in. (1 Nm).
(14)
Connect batteries (para 7-57).
2-485
|