TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
Install two grommets (8) in box (3).
(3)
Apply grease to grommets (8) and two
(4)
wires (9 and 10) and install wires
through grommets.
Connect two wires (9 and 10) to
(5)
receptacle (1) with two lockwashers (11)
and screws (12).
NOTE
If a slave cable with a small receptacle plug
is being used, the retention arm needs to
be bent 35. Do step (5.1).
(5.1) If slave cable with a small receptacle
plug is being used, bend retention
arm (12.1) 35.
(5.2) Install arm (12.1) and spring (12.21 on
base (12.3) with screw (12.4) and
nut (12.5).
(6) Install gasket (13) in cover (14).
(7) Install cover (14) and retention
device (14.1) on box (3) with four
screws (15).
7-348.1/(7-348.2 blank)
Change 3
|