TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-92.1. NATO SLAVE RECEPTACLE AND BOX REMOVAL/REPAIR/INSTALLATION
(CONT).
Remove four screws (11), washers (12),
(5)
locknuts (13), and cap assembly (14)
from receptacle (7).
Remove receptacle (7), insulator (15),
(6)
and plastic insulator (15.1) from box (3).
c. Assembly.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. lb avoid injury or death, keep away from open fire
and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
NOTE
When installing receptacle, make sure positive terminal (+) is on right side of box.
M983 Tractors have a slave cable retention device on the NATO slave cable
connector box. Other models do not.
Insulator located between receptacle and box may be either plastic or rubber
material. Rubber insulator does not need adhesive-sealant applied. Perform step (1)
for plastic insulator only.
Apply silicone adhesive-sealant to both sides
(1)
of plastic insulator (0.1).
(1.1) Install receptacle (1), plastic insulator (0.1),
and insulator (2) in box (3).
(2)  Install cap assembly (4) in receptacle (1)
with four screws (5), washers (6), and
locknuts (7). Put cap on receptacle.