Electrical System Maintenance Instructions (Cont)
7-86. TLI TANK LEVEL INDICATOR GAGE AND BRACKET REMOVAL/INSTALLATION (M978)
(CONT).
WARNING
Adhesives, solvents, and sealing compounds can
burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in
well-ventilated area. If adhesive, solvent, or
sealing compound gets on skin or clothing, wash
immediately with soap and water.
(7) Coat threads of pipe nipples (16 and 17) with
pipe thread sealing compound and install into
elbow (18) and junction-box (19).
CAUTION
To avoid damage to wires, do not
connect wires until indicator box
has been installed on pipe.
(8) Install adapter (20) in indicator
box (14) and feed wire (3),
wire (4), and wire (13) into
control junction box (19).
(9) Apply pipe thread sealing
compound to threads of pipe
nipple (18) and install
adapter (20) and indicator
box (14) on pipe.
(10) Install three wires (3, 4, and 13)
and three screws (22).
(11) Install bracket (23) with two
screws (24 and 25),
lockwashers (26 and 27), and
nut (28).