TM
9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
b. Installation.
(1) Position TLI TANK LEVEL
INDICATOR gage (1) in cover (2)
and install wire (3) and wire (4)
with washers (5) and nuts (6).
(2) Install lamp (7) in clip socket (8).
(3) Install clip socket (8) in TLI
TANK LEVEL INDICATOR
gage (1).
(4) Install gasket (9) and bracket (10) on TLI
TANK LEVEL INDICATOR gage (1) with
two lockwashers (11) and nuts (12).
(5) Install three wires (3, 4, and 13)
through indicator box (14).
(6) Install TLI TANK LEVEL
INDICATOR gage (1), cover (2),
and gasket (9) with three
screws (15).
7-308
|