TM 9-2320-279-20-1
Electrical System Maintenance Instructions (Cont)
7-3. ALTERNATOR AND PULLEY REMOVAL/INSTALLATION (CONT).
(5)
Clamp pulley (13) in vise with soft jaws.
(6)
Loosen locknut (14) until shaft (15)
turns.
(7)
Using lockjaw pliers, hold inside flange
(16) of pulley (13) and remove
locknut (14).
NOTE
There are two types of alternator pulleys. Model
A has no key, while Model B includes one.
(8)
Remove pulley (13) from vise and
remove pulley and key (16.1) from
shaft (15).
b.
Installation.
NOTE
There are two types of alternator pulleys.
Model A has no key, while Model B
includes one.
(1)
Install key (1) and pulley (1.1) on
shaft (2).
(2)
Clamp pulley (1.1) in vise with soft jaws.
(3)
Install locknut (3) on shaft (2) and
tighten until shaft (2) begins to turn.
(4)
Using lockjaw pliers, hold inside
flange (4) of pulley (1.1) and tighten
locknut (3) to 70 to 85 lb-ft (95
to 115 NSm).
(5)
Remove lockjaw pliers and
re-torque locknut (3).
Change 5
|