9-2320-279-20-1
Troubleshooting Malfunctions (Cent)
q
2-9. Troubleshooting
Malfunction
Test or Inspection
q
Corrective Action
TANKER SYSTEM
11. TANK LEVEL INDICATOR GAGE DOES NOT REGISTER PROPER FUEL LEVEL
MALE
SOCKET
CON
Step 14. Disconnect phototransistor connector. Set TLI TANK LEVEL
switch to ON.
Ground each female pin of phototransistor connector (male socket and female pin). Check
that TLI TANK LEVEL INDICATOR gage drops from FULL to approximately 3/4.
If TLI TANK LEVEL
gage does not drop from FULL to approximately
3/4, replace tank level indicator adjuster
cover (para 7-47).
Step 15. Disconnect LED connector (female pin and male socket). Set TLI TANK LEVEL
switch to ON. Check for 24 to
at each female pin.
replace tank level indicator adjuster (para 7-87).
If voltage is less than
gage does not register,
fuel level sensor
Step 16. If TLI TANK LEVEL
q