TM 9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
TANKER SYSTEM (CONT)
7. CANNOT EVACUATE FUEL FROM HOSES OR PRIMARY PUMP STOPS OR FAILS TO
DELIVER RATED FLOW (CONT).
Step 4. Check for defective air actuator system. Remove airhose from V5 air actuated flow valve.
Operate HAV HAND ACTUATED CONTROL VALVE (TM 9-2320-279-10). Check for air
blowing out of hose and for continuous exhausting of air from HAV HAND ACTUATED
CONTROL VALVE.
If no air, or if HAV HAND ACTUATED CONTROL VALVE continuously exhausts air,
repair HAV HAND ACTUATED CONTROL VALVE (para 18-16).
Step 5. Check that V5 air actuated flow valve fully opens. Open V5 air actuated flow valve with
wrench.
Replace defective V5 air actuated flow valve (para 25-19).
Step 6. Check flow limiting valve and piping for damage, dirt, and debris (para 25-11, pipes 5
and 8).
Remove dirt and debris from flow limiting valve and piping. Replace damaged
piping. Replace damaged flow limiting valve (para 25-34).
Step 7. Remove filter-separator cover (para 23-4). Check for dirt and debris.
Replace dirty filter-separator elements.
Step 8. Remove V6 FUEL/DEFUEL CONTROL VALVE (para 25-20) and piping (para 25-11). Check
for damage, dirt, and debris.
Remove dirt and debris. Replace damaged V6 FUEL/DEFUEL CONTROL VALVE.
Step 9. Remove eductor (para 25-33) and piping (para 25-11). Check for damage, dirt, and debris.
Remove dirt and debris. Replace damaged eductor or damaged piping.
|