Click here to make tpub.com your Home Page

Page Title: CRANE CONTROLS STICKING.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM
9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
MATERIAL HANDLING CRANE (M977, M985, M984E1) (CONT)
9. CRANE CONTROLS STICKING.
Step 1. Check high pressure hydraulic filter for contamination.
If contamination is found, determine cause of contamination. Drain reservoir,
replace strainers (para 13-11) (M984E1: para 13-15), change high pressure filter
(para 19-17) and return line filter (para 13-8) (M984E1: para 13-13). Fill with oil
(LO 9-2320-279-12), then purge system by operating crane (TM 9-2320-279-10).
Step 2. If problem remains, notify the supervisor.
10. REMOTE CONTROLLER WILL NOT OPERATE CRANE OR OPERATES ABNORMALLY.
Step 1. Make a visual check of remote controller cable for loose connectors.
Tighten loose connectors. Replace remote controller cable if there are more than
two broken wires.
Step 2. Check each wire in remote controller cable for zero ohms between both ends of cable.
If meter does not show zero ohms in any wire, repair defective wire.
If more than two wires are defective, repair remote controller cable (para 17-23.1).