TM
9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
2-15. TROUBLESHOOTING INSTRUCTIONS (CONT).
Table 2-9. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
MATERIAL HANDLING CRANE (M977, M985, M984E1) (CONT)
REMOTE CONTROLLER WILL NOT OPERATE CRANE OR OPERATES ABNORMALLY
10.
(CONT).
Step 3. Check for defective remote controller. Set multimeter to X1K. Set remote controller switch
to ON and place negative (-) probe on pins as shown, with positive (+) probe always on pin
H. As each crane function control is operated, meter should show zero to 15 ohms.
If meter does not show zero to 15 ohms in all control functions, replace defective
remote controller assembly on/off switch (para 17-23).
2-205
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |