![]() TM 9-2320-279-20-1
Table 2-2. Unit Level Preventive Maintenance Checks and Services
Interval
Item To Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
M978
Continued
15.05
Annually Flowmeter
WARNING
Strainer
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To
avoid injury or death, keep away from fire
and use in a well-ventilated area.
If
adhesives, solvents, or sealing compound get
on skin or clothing, wash immediately with
soap and water.
CAUTION
Never tap strainer ends on a hard surface to
dislodge particles. Failure to comply may
dent strainer, resulting in improper strainer
assembly, poor sealing, and leaks.
NOTE
The flowmeter strainer assembly must be
removed (paragraph 25-8) to perform the
following service. After service is completed,
reinstall flowmeter strainer assembly
(paragraph 25-8).
a. Clean the strainer basket with dry clean-
Strainer basket missing
ing solvent and brush.
or damaged.
b. Clean inside the strainer housing, inner
face of cover plate, mating face of the strainer
body, and seal ring with a clean, soft, shop
rag.
Change 8
|