T M 9-2320-211-34-2-1
d.
Cleaning. There are no special cleaning procedures needed. Refer to
c l e a n i n g procedures in para 1-3.
e.
I n s p e c t i o n and Repair.
FRAME 1
1.
Check that mounting flanges on manifolds (1, 2, and 3) and manifold elbow (4)
a r e not scratched. Take off scratches with file or crocus cloth.
2.
Check that four elbow studs (5) and 30 manifold studs (6) are not bent or
broken and that threads are not damaged. If studs are broken, drill them out
and retap holes. Get new studs in place of damaged ones.
3.
Check that manifolds (1, 2, and 3) and manifold elbow (4) are not cracked.
W e l d cracks. Refer to TM 9-237. If more repair is needed, get a new part.
4.
C h e c k that 12 threaded holes (7) are not damaged. Retap damaged holes.
5.
C h e c k that two hoses (8) have no cracks, tears or dry rot. If hoses are
damaged, get new ones.
END OF TASK
|