TM 9-2320-211-34-2-1
FRAME
2
NOTE
R e a d i n g s must be within limits given in table 2-2. If
r e a d i n g s are not within given limits, throw away part
and get a new one.
1.
Measure t w o p l u n g e r b o r e s ( 1 ) .
Measure o u t s i d e diameters of two plungers (2).
2.
3.
Measure f i t between two plunger bores (1) and two plungers (2).
Measure f r e e l e n g t h o f t w o s p r i n g s ( 3 ) .
4.
5.
Measure s q u e e z e d length of two springs (3), using 7. 65-pound load.
6.
Measure s o l i d length of two springs (3).
Oil Cooler Housing Wear Limits
S i z e and Fit
Index
of New Parts
Wear Limit
Number
(inches)
Item /Point of Measurement
(inches)
1
P l u n g e r bore inner diameter
0.8050
0.8030 to 0.8040
2
V a l v e plunger outer diameter
0.8000 to 0.8010
0.7990
1 and 2
F i t of plunger in bore
0.0060
0.0020 to 0.0040
3
S p r i n g (free length)
1.6200
None
Spring
width
(7.65-pound
load)
3
1.3800
None
S p r i n g solid height
3
0.9520 maximum
None
|