TM 9-2320-211-34-2-1
WARNING
Dry cleaning s o l v e n t is flammable. Do not use
n e a r an open flame. K e e p a fire extinguisher
n e a r b y w h e n s o l v e n t i s u s e d . U s e only in well-
v e n t i l a t e d p l a c e s . Failure to do this may result
i n injury to personnel and damage to equipment.
Clean all parts with solvent. Dry using lint-free cloth.
Cleaning.
d.
I n s p e c t i o n and Repair.
e.
FRAME 1
1.
C h e c k that housing (1) and cover (2) have no cracks. If cracks are found,
g e t a new part.
2.
P l u g one opening (3) in cooler core (4). Put a 150 psi air source into the
other opening.
Put cooler core (4) under water. Check that cooler does not leak. If cooler
3.
l e a k s , get a new one.
4.
Check that gasket surface on cooler core (4) is smooth. Take off rough spots
u s i n g crocus cloth.
C h e c k that plungers (5) have no scratches or burrs. Polish plungers with
5.
crocus cloth.
GO TO FRAME 2
|