TM 9-2320-211-20-3-1
b.
Replacement.
WARNING
Smoking, sparks or open flame are not allowed
within 50 feet of work area during- this task. Fire
or explosion could occur, causing injury to person-
nel and damage to equipment.
Put two gaskets (1) in place in filter head (2).
1.
2.
Put two filter elements (3) in two filter housings (4) and place them near filter
head (2).
3.
Push two filter housings (4) up into filter head (2).
4.
Using 5/8-inch wrench, screw on and tighten two plugs (5) on two bolts (6).
Close two drain cocks (7) by turning them to right.
5.