FRAME 2
Place container under filter housings (l).
1.
2.
Open two drain cocks (2) by turning them to left.
When all fuel has drained out from filter housings (1), using 5/8-inch wrench,
3.
unscrew and take out two plugs (3).
Pull down and take out two filter housings (1).
4.
Pull out two filter elements (4) from filter housings (1). Throw filter elements
5.
away.
Take out two gaskets (5) from filter head (6) and throw gaskets away.
6.
Take out container. Put fuel in approved disposal area.
7.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when solvent
is used. Use only in well-ventilated places. Failure to do
this may result in injury to personnel and damage to equip-
ment.
8.  Clean filter housings (1) with solvent.
END OF TASK