a.
Remove
(1)
Note the position of and remove the electrical cables (1) to the A-Frame Junction Box (2).
(2)
Remove the four screws and lock washers (3) securing the Junction Box (2) to the A-
Frame. Discard the lock washers.
(3)
Remove the Junction Box (2).
(4)
Examine all threaded components for wear and damage.
(5)
Check the electrical harnesses for damage.
(6)
Change components as required.
b.
Install
(1)
Apply thread-locking compound to the screws.
(2)
Fit the Junction Box (2) to the A-Frame with the four lock washers and screws (3).
(3)
Fit the electrical cables (1) to the positions noted during removal.
|