5 - 048 LAUNCH FRAME - EMERGENCY WINCH DRUM RELEASE
This task covers:
a. Align
INITIAL SETUP:
Tools Required
Tool Kit, General Mechanic's, Automotive (GMTK)
Materials Required
None
Equipment Conditions
A-Frame deployed
WARNING
INJURY FROM EXTREME HYDRAULIC OIL PRESSURE. THE SYSTEM MUST BE
DE-PRESSURIZED BEFORE CARRYING OUT THE EMERGENCY WINCH DRUM
RELEASE PROCEDURE.
SLIP AND FALL INJURY. PERSONNEL MAY SLIP ON SPILLED HYDRAULIC
FLUID. SUITABLE CONTAINERS AND FLUID ABSORBENT MATERIALS ARE TO
BE USED TO CONTAIN SPILLAGE.
NOTE
In the event of a power failure the drum brake will be applied and the drum will not rotate.
This procedure details the actions necessary to release the drum in an emergency.