5 - 024 A-FRAME - BACK-UP MODE OPERATION CONTROLS
This task covers:
a. Remove
b. Install
INITIAL SETUP:
Tools Required
Tool Kit, General Mechanic's, Automotive (GMTK)
Materials Required
Thread locking compound, loctite 243
Nyloc nuts (Qty 4)
Equipment Conditions
A-Frame deployed
WARNING
INJURY FROM EXTREME HYDRAULIC OIL PRESSURE. THE SYSTEM MUST BE
DE-PRESSURIZED BEFORE CARRYING OUT ANY WORK ON THE BACK-UP
MODE OPERATION CONTROLS.
SLIP AND FALL INJURY. PERSONNEL MAY SLIP ON SPILLED HYDRAULIC FLUID.
SUITABLE CONTAINERS AND FLUID ABSORBENT MATERIALS ARE TO BE USED
TO CONTAIN SPILLAGE.