Page Title: Remove
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-5420-279-23
1
2
2
3
a.
Remove
(1)
De-pressurize the hydraulic system. Refer to unit maintenance procedure 5-118.
(2)
Disconnect the hydraulic pipes (2) connected to the back-up mode operation controls (1).
(3)
Remove the four nyloc nuts, six bolts and six washers (3) mounting the back-up mode
operation controls to the A-Frame. Discard the nyloc nuts.
(4)
Remove the back-up mode operation controls (1).
(5)
Examine all threaded components for wear and damage.
(6)
Change components as required.
b.
Install
(1)
Apply thread-locking compound to the six mounting bolts.
(2)
Fit the back-up mode operation controls (1) to the mounting bracket on the A-Frame with
the four nyloc nuts, six bolts and six washers (3).
(3)
Fit the hydraulic pipes (2) to the back-up mode operation controls (1).
c.
Follow on task
(1)
Operate the system and check for correct operation and hydraulic fluid leaks.
5-116