TSUM - 2-013 Boom Bridge Forward Level Bank (56) Part 3
Part 3
All Maintainer
Tasks
Fit pressure gauge
Gauge to TPB7 on
Launch Fram e Pilot
Manifold
Operate joystick to
carriage out
W ith joystick operated to
Does
carriage out - m anually
Go to Part
gauge read 363
No
Yes
operate SV8 on
4
psi (2500
Launch Fram e Pilot
kPa)
Manifold
Does
Fit pressure
Replace solenoid coil
gauge read 363
gauge to TPP2 on
Yes
No
on SV8. See m aintenance
psi (2500
Launch Fram e
procedure 5-124
kPa)
Pilot Manifold
Replace 363 psi (2500 kPa)
Does
Replace SV8
pressure reducing valve. See
gauge read 363
valve assem bly.
No
Yes
m aintenance procedure 5-130,
psi (2500
See m aintenance
item 5
kPa)
procedure 5-122