TM 1-1510-223-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
NOTE
For maximum cooling on the ground, turn the PNEU &
ENVIRO BLEED AIR valve switches to PNEU ONLY position.
Verify airflow is present from aft cockpit eyeball outlets to
ensure sufficient cooling for mission equipment.
Check may also be accomplished by switching the # 1
GENERATOR OFF and leaving the #2 GENERATOR ON.
* 4.
AC/DC power/current limiters/inverters - Check as follows:
a.
# 1 GENERATOR switch - ON.
b.
# 2 GENERATOR switch - OFF.
c.
# 1 and # 2 INVERTER switches - ON.
Check for the following indications:
(1) # 1 and # 2 INVERTER annunciator lights
not illuminated.
* (2) AC frequency - 394 to 406 Hz.
* (3) AC voltage - 104 to 124 VAC.
* (4) DC voltage - 28 to 28.5 VDC.
(5) Battery ammeter
-
Check
for
charge
indication.
NOTE
This procedure checks both 400 and 500 ampere current
limiters that tie the aircraft bus systems together.
d.
# 2 GENERATOR switch - ON.
5.
AUTO PLT POWER switch - ON.
2-41
|