TM 1-1510-223-MTF
C41.
Standby fuel pump inoperative.
a.
Defective standby pump.
b.
Defective switch in fuel management panel.
C42.
Pneumatic surface or antenna deice system inoperative.
a.
Defective surface deice time delay module.
b.
Defective deice distributor valve.
c.
Defective plumbing.
d.
Defective boot.
C43.
Right and left FIRE PULL warning lights do not illuminate
in test position of fire protection test switch.
a.
Tripped fire detector circuit breaker.
b.
Defective fire protection test switch.
c.
Defective wiring.
C44.
Engine fire detection system wholly or partially
inoperative.
a.
Defective sensing tube.
b.
Defective fire detector.
c.
Defective ENG FIRE TEST switch.
C45.
FIRE DETR circuit breaker trips.
Short circuit in wiring or components.
C46.
Left FIRE PULL warning light illuminates in test position
but right FIRE PULL warning light does not.
a.
Defective right fire detector.
b.
Defective wiring between fire warning power circuit
breaker and right fire detector.
C47.
Right FIRE PULL warning light illuminates in test position
but left FIRE PULL warning light does not.
a.
Defective left fire detector.
3-13
|