3-5. Daily Preventive Maintenance Checks and Services Chart
Sequence
No.
Item
Procedure
References
1
Exterior surfaces.
Clean the maintenance kit panel and the meter.
Check for broken meter glass.
2
Knobs, switches and
a. During operation see that the knobs, switches, and
lamps.
lamps operate properly.
b. Tighten any loose knobs with a No. 8 hex- wrench.
c. Replace all burned-out lamps.
d. If trouble remains, contact higher level maintenance
for repair.
3
Operational test.
During operation, be alert for any unusual operating
indications. If any unusual indications occur, remove
through 2-8.
all power and contact higher level maintenance for
repair.
3-6. Cleaning
37. Monthly Preventive Maintenance
Checks and Services
Caution:  Do not use any cleaning solvent
on the front panels or anywhere there is silk
Perform the maintenance functions indi-
screening.
cated in the monthly preventive maintenance
Inspect the exterior of the test unit, radio
checks and services chart (para 38) once each
set simulator, and the transit case.  The ex-
month in addition to the daily preventive maint-
enance checks and services  (para 3-5). A
terior surface should be free of dirt, grease,
and fungus.
month is defined as approximately 30 calendar
days of 8-hour-per-day operation. Adjustment
Caution:  Do not press on the meter face
of the maintenance interval must be made to
when cleaning; the meter may become dam-
compensate for any unusual operating condi-
aged.
tions.  Equipment maintained in a s t a n d b y
a. Remove all loose foreign material with a
(ready for  immediate operation) condition
clean lint-free cloth.
must have monthly preventive maintenance
b. Remove grease  fungus, and ground-in
checks and services performed on it.  Equip-
dirt with a cloth dampened (not wet) with
ment in limited storage (requires service be-
water and a mild soap.
fore operation) does not require monthly pre-
c. Remove dust or dirt from the connectors
ventive maintenance.
with a soft-bristled brush.
38. Monthly Preventive Maintenance Checks and Services Chart
Sequence
References
Procedure
No.
Item
None
a. Inspect the cables and flexible module extenders for
1
Cables, flexible module
deterioration and damage, such as cuts, cracks, or
extenders, and rigid
frayed insulation. Repair minor damage to insula-
module extenders.
tion by covering the damaged area with rubber
electrical's tape. Replace defective cables.
b. Inspect the rigid module extenders for damage such
as bent or missing connector pins. Refer to
higher category for repair.
None.
a. Hand check these exterior items for looseness.
2
Connectors, handle grips,
Tighten all loose exterior items.
jacks, and screws.
b. See that there are no loose or missing screws.
Replace missing screws and tighten all loose
screws.
3
Inspect all exposed metal surfaces for rust and
Exterior surfaces.
corrosion. Touch up surfaces.