TM 9-2815-210-34-2-2
Table 6-9. Run-In Schedule - Short (Model LDS-465-1A)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 265F. Oil pressure is measured
a t engine oil gallery.
Fuel
G r o s s Brake
( D F - 1 of
E n g i n e Speed
Duration
( b a r e engine)
VV-F-800)
(rpm)
Period
(minutes)
0
0
1
P r e l u b r i c a t e at 25
(minimum)
p s i (measured at
e n g i n e oil gallery)
Diesel
1400
40
2
10
Diesel
2200
120
15
3
4
R e t i g h t e n cylinder head nuts to 130 pound-feet (157 pound-feet for
T D block) and set valves immediately following period 3.
140
Diesel
15
2600
5
Diesel
10
2600
170 to 180
6
7
S e t high speed adjusting screw to limit maximum speed, no load
2850 to 2900 rpm.
Diesel
175 to 185
8
Set full load
2600
(83 lb/hr
power
m a x . fuel
flow )
Diesel
9
(37 to 39
Set droop screw
1200
lb/hr
fuel
or
flow )
1400
Diesel
(44 to 45
lb/hr
fuel
flow )
P o w e r check full
2000
4 2 5 pound-
Diesel
10
f e e t torque
load
(rein)
(70 lb/hr
m a x . fuel
flow)
11
Diesel
650 to 700
S e t low idle adjust-
0
ment
Diesel
12
A s needed to check
for leaks
|