TM 9-2815-210-34-2-2
e.
Flow test.
WARNING
Smoking, sparks or open flames are not allowed
w i t h i n 50 feet of work area during this task.
F i r e or explosion could occur, causing injury
t o personnel and damage to equipment.
NOTE
This is an alternate procedure included for ref-
e r e n c e p u r p o s e s o n l y . S t a n d a r d procedure is to
t e s t fuel pump during dynamometer test and
adjustment.
FRAME 1
1.
S e t rheostat (1) until voltmeter (2) reads 10 volts.
2.
S e t adjustable valve (3) until pressure gage (4) reads 60 psi.
Pump (5) should flow a minimum of one pint in 2 minutes and 45 seconds.
3.
T u r n off rheostat (1) and open adjustable valve (3) to bleed off pressure.
4.
5.
T a k e out pump (5) from test setup.
T a k e apart test setup.
6.
END OF TASK
|