|
|
TM 9-2815-210-34-2-2
d.
L e a k Test.
S m o k i n g , sparks or open flames are not allowed
w i t h i n 50 feet of work area during this task.
F i r e or explosion could occur, causing injury
t o personnel and damage to equipment.
NOTE
This is an alternate procedure used for ref-
erence purposes only. Standard procedure is
t o test for leaks during dynamometer test and
adjustment.
FRAME 1
1.
H o o k up hose (1) from supply tank (2) of diesel fuel to pump inlet (3).
2.
H o o k up hose (4) from pump outlet (5) to adjustable valve (6).
H o o k up pressure gage (7) from adjustable valve (6).
3.
H o o k up hose (8) from pressure gage (7) to nozzle and check valve assembly
4.
(9), inlet (10), and outlet (11).
GO TO FRAME 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |