TM 9-2815-210-34-2-2
FRAME 3
NOTE
R e a d i n g s must be within limits given in table 4-50. If
r e a d i n g s are not within given limits, throw part away and
get a new one.
I n t a k e valves (1) are bigger than exhaust valves (2).
U s i n g d e p t h micrometer, measure length of three intake valves (1) from tip
1.
t o gage line as shown.
U s i n g depth micrometer, measure length of three exhaust valves (2) from tip
2.
t o gage line as shown.
GO TO FRAME 4
Table 4-50. Intake and Exhaust Valve Length Wear Limits
Size and Fit
Wear Limit
of New Parts
Index
(inches)
(inches)
Item /Point of Measurement
Number
I n t a k e valve length from tip to
1
6.0980
6 . 0 8 2 0 to 6.0880
g a g e line
E x h a u s t valve length from tip
2
6.0860
6 . 0 7 0 0 to 6.0760
t o gage line
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |