FRAME 3
WARNING
D r y cleaning solvent is flammable. Do not use near an
o p e n flame. K e e p a fire extinguisher nearby when sol-
v e n t i s u s e d . U s e only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
d a m a g e to equipment.
1.
C l e a n six piston cooling nozzles (1) and six nozzle mounting screws (2) with
dry cleaning solvent.
WARNING
E y e shields must be worn when using compressed air.
E y e injury can occur if eye shields are not used.
2.
C l e a n oil passages in six piston cooling nozzles (1) using brass wire probes.
B l o w compressed air through oil passages.