TM 9-2520-246-34-1
FRAME 5
NOTE
Readings must be within limits given in table 2-52.
The letter T indicates a tight fit. If readings are
not within given limits, throw away part and get
a new one.
Measure diameter of dowel pin (1).
1.
2.
Measure dowel pin bore (2).
3.
Measure fit of dowel pin (1) in bore (2).
GO TO FRAME 6
Transfer Case Dowel Pin Wear Limits
Table 2-52.
Size and Fit
Wear Limit
of New Parts
Item/Point of Measurement
(inches)
(inches)
Index Number
None
Dowel pin diameter
0.7500 to 0.7510
1
0.7480
0.7461 to 0.7472
Dowel pin bore
2
0.0020T
0.0028T to 0.0049T
Fit of dowel pin in bore
1 and 2
2-213
|