TM 9-2520-246-34-1
FRAME 5
NOTE
Readings must be within limits given in table 2-32.
The letter T indicates a tight fit. If readings are
not within given limits, throw away part and get
a new one.
Measure diameter of dowel pin (1).
1.
Measure dowel pin bore (2).
2.
Measure fit of dowel pin (1) in bore (2).
3.
GO TO FRAME 6
Transfer Case Dowel Pin Wear Limits
Table 2-32.
Size and Fit
Wear Limits
of New Parts
(inches)
(inches)
Item/Point of Measurement
Index Number
None
0.7501 to 0.7503
Dowel pin diameter
1
0.7498
0.748 to 0.749
Dowel pin bore
2
0.0003T
0.011T to 0.0023T
Fit of dowel pin in bore
1 and 2
2-192
|