E-24. M1089 30K WINCH PNEUMATIC TEST ADAPTER
Assembly the M1089 30K winch pneumatic test adapter to the following steps. Refer to the following parts list and
Figure E-18. M1089 30K Winch Pneumatic Test Adapter for details.
Part Number
Material Description
National Stock Number
Qty.
NB-4-035
Tubing, Nonmetallic
14 in. (355.6 mm)
MIL-T-27730
Tape, antiseizing
1 roll
207P-4
Coupling, Pipe
1
4-6 100102 BA
Adapter, Straight, Pipe to
1
Tube
4-4 100101 BA
Nipple, Tube
1
Figure E-18. M1089 30K Winch Pneumatic Test Adapter
a.
All dimensions are in inches (millimeter).
b.
Cut piece of nonmetallic tubing (1) to 14.0 in. (355.6 mm).
c.
Remove two nuts (2), ferrules (3), and sleeves (4) from tube nipple (5).
d.
Install nut (2), ferrule (3), and sleeve (4) on nonmetallic tubing (1).
e.
Install nonmetallic tubing (1) on tube nipple (5).
f.
Remove nut (6), ferrule (7), and sleeve (8) from straight adapter (9).
g.
Install nut (6), ferrule (7), and sleeve (8) on nonmetallic tubing (1).
h.
Install nonmetallic tubing (1) on straight adapter (9).
i.
Apply on wrap of antiseizing tape to threads of straight adapter (9).
j.
Install pipe coupling (10) on straight adapter (9).
k.
Retain nut (2), ferrule (3), and sleeve (4) for future use.